Laser module X LS Macarrn termoencogible L41 L L37 L LWL1 X DX83 L L83 LWL2 L DX77 DX Board DX6 This board is not available as a spare part or a repair part. X-ray tube assemblies can only be ordered as complete units. DX61 This board is not available as a spare part or a repair part.
The diaphragm unit can only be ordered as a complete unit. Board DX7 The board is not available as a spare part or a repair part. The Easypad can only be ordered as a complete unit. Therefore: avoid direct sunlight and bright room lighting above the unit! Reattach all covers. When attaching the covers: be sure to screw the sheet metal cover back on. Exposure time: See "Program values". Image acquisition scale: For P1, normal dental arch slice center approx.
Exposure time for a Depending on the tube load, interval times of 8 s to s are automatically set by the system. Example: For program P1 with exposure. Equipment class: IPX0 Protection class. Class I device Degree of protection against electric shock: Type B device Degree of protection against Ordinary equipment without protection ingress of water: against ingress of water Year of manufacture:.
Active sensor area, Pan type: x 6 mm Pixel size: 0. Digital Flat Panel Detector with a-Si technology amorphous silicon. With 3D exposure technology: Active sensor area mm x mm Pixel size: 0. Active sensor area, Ceph mm x 6. Processor 2. If a module software version does not match the main software version, the main software version is identified with an asterisk on the info screen e. Main software V No person may be positioned in the unit when it is switched on.
NOTICE Damage to the unit Make sure that no objects are in the movement range of the device when it moves exception: Calibration block and positioning aids.
Electrical components are destroyed by short circuits. Do not switch the unit on until the temperature of the unit has adapted to the ambient temperature and the condensation has evaporated. Also note the operating temperature specified for this device. Constant switching on and off reduces the service life of individual unit components and results in increased power consumption.
After switching the unit off, wait for approx. The touchscreen can be damaged or its surface scratched. Never use pointed objects such as ballpoint pens, pencils, etc. Only use your fingertips to operate the touchscreen. At the same time, the self-adjustment routine for the mechanics and the electronics of the unit is performed. If a key is pressed during the self- adjustment routine, an error message will display on the control panel. Turn the main switch A to position I.
Wait for approx. A B The radiation indicator X-ray C lights up for approx. For a number of seconds the height adjustment keys light up blue, then quickly change to green. After approx. This LED remains lit as long as the unit is on. The start screen is displayed on the touchscreen for several seconds. The program selection is then displayed on the touchscreen.
The forehead support and temple supports are completely open. Check whether the patient symbols on the touchscreen can be selected in exactly the right position. If problems occur during selection, adjust the touchscreen [ ]. English is preconfigured as the unit language. The preview image is switched on. The welcome screen is switched on. The first name, last name and date of birth lines are displayed on the welcome screen.
Ambient light background lighting is set to "white". If the customer requires a different configuration, this can be implemented via service routine S or the Web service ambient light. Each X-ray component must be assigned a unique IP address and the name of the X-ray component must also be unique.
To find out whether an IP address already exists in the network, enter the. Switch on all network devices computers, printers, X-ray components which have been operated to date. Invoke the input prompt DOS window from a network computer. At the prompt, enter "ping" followed by the address to be checked and then press the Enter key. Example: ping The "Sirona AcquisitionServer" software is installed. If necessary: Select the acquisition server from the "Acquisition Server" list field.
Click on the "Next" button. A password dialog box appears. Enter the service password and confirm your input by clicking the "OK" button. Menu for adding X-ray components The menu for adding X-ray components opens. There are three options for adding X-ray components: "Automatic search" "Boot service" "Add device manually". The menu for adding X-ray components opens.
Click the "Automatic search" button in the structure tree. The network is searched for available X-ray components. The X-ray components found on the network are displayed in list form.
NOTE: If no X-ray component is found, check the availability of the unit and repeat the "Automatic search" or use the "Add device manually" function. Selecting an X-ray component 2. Select the preferred X-ray component and enter "Location" in the text box in the location of the X-ray component. Click the "Save" button to save the settings.
Wait until the saving operation has been completed. Then click the button marked "Exit". The menu closes. Click on the "Cancel" button. Click the "Boot service" button in the structure tree. A message window prompts you to switch the new X-ray component back on to reboot. The network is searched for the "booting" X-ray component.
The X-ray components found in the network is displayed with their network data. Adapt the network configuration IP address, subnet mask and the standard gateway to your network.
If you receive an error message when saving the network configuration, the network data entered are probably invalid. Repeat the entire procedure with valid network data. Click the "Add device manually" button in the structure tree. The workstation software for the corresponding X-ray component or sensor is installed on the workstation. Click on the "Device configuration" button. The "Device configuration" menu opens. Click on the "Device details" button in the structure tree and then on the "Show Information" button.
Click on the "Downloading" button to load and save the current unit information for the unit. You have a certificate containing a valid activation key code.
A Level 1 is displayed on the touchscreen. Touch the toothed wheel A in the selection image. Level 2 is displayed. Touch the keyboard icon B. B A keyboard then appears. Enter the activation key from the certificate via the keyboard. C Once the final character is entered, the enter key C appears. Tip: The activation key code consists of 16 characters.
Confirm your input with the Enter key C. The function enhancement is activated. If the entry contains errors,! The function enhancement has failed. Compare the activation key code displayed with the activation key code on the certificate.
If you cannot detect an input error, contact the responsible sales partner. A Level 2 is displayed. Touch the question mark in the bottom right corner. G The name of the function enhancement is displayed. As an alternative to entering the access code via the Easypad, the activation key code can also be entered via an internet browser.
The unit and computer are turned on. The unit is logged into the network as an X-ray component. Start an Internet browser such as Internet Explorer or Firefox. Confirm your input with the "Enter" key.
A security prompt appears. Click on the link "Continue to this Website". NOTE: Javascript must be enabled. The Sirona Web service is loaded. The sub menus of the "User" menu are displayed in the structure tree. In the structure tree, click on the "ActivationCode" element.
A page with an input field is opened. Enter the activation key code from the certificate in the field. Confirm your entry with the "Enter ActivationCode" button. The first time you establish contact with the X-ray device, a certificate check operating system function should be performed. If no certificate check has been performed, the "Security Alert" dialog box is displayed every time a connection is established to the X-ray device.
The "Security Alert" dialog box is opened. Click on the "View Certificate" button. The "Certificate" dialog box opens. Click on the "Install Certificate" button. The "Certificate Import Wizard" opens. Select the "Automatically select the certificate store based on the type of certificate" option panel. Click on the "Finish" button. The "Security Warning" window then opens. If the fingerprint matches, click on the "Yes" button. If the fingerprint does not match, contact your local sales partner.
The confirmation window opens with the message "The import was successful". Click on the "OK" button. The certificate check has been performed.
Unit inoperability! Before starting the firmware update, make sure that no unit movements are active. Otherwise the system may become inoperable in rare cases. The sensor unit must be installed as part of the update. These sources always contain the latest information on software updates. Starting the software update 3. Select the desired X-ray component in the list marked "Device administration".
Then click on the "Software update" button. The dialog box for entering the service password opens. Enter the first 4 digits of the current system date in reverse order e. Enter the service password. Click the "OK" button to confirm the entry. The connection to the Acquisition Server is established.
The update menu opens. Click on the "Browse" button and select the desired update file. The update file is located on the unit software CD. It is delivered with each DX11 replacement board and also included in the country set.
Click on the "Update starten" button to start the firmware update The firmware update is started. A dialog window showing the progress tells you the status of the upload. After the firmware update, the message window in the update menu shows whether the update was successful or not. In addition, a message in the software manager notifies you that a unit restart is required to activate the firmware update you performed.
A new DX11 or DX83 version will run only after the unit has been rebooted see also chapter "Measures following replacement of boards [ ]". Any errors with the consecutive numbers 01, 03, 04, 06, or 07 displayed immediately following the firmware update may be ignored. If these messages appear again after the system is rebooted, please carry out troubleshooting as described in the "List of error messages [ 84]" section. If any conspicuous problems occur in connection with system handling after the firmware update and unit reboot has been completed, please repeat the firmware update immediately.
After a successful firmware update, the log file produced by the unit is displayed in the update menu. Check the log file to make sure that the update was completed successfully. If the log file contains entries such as "Update of DXxx failed! Repeat this procedure as often as necessary until the "failed messages" no longer appear. Restart the unit now. Use the "Device details" or service routine S If you want to save the "Device details" : Open the "Device details" [ 59].
Click on the "Show Information" button. Click on the "Download" button. Select the storage location you desire. Click on the "Save" button. The "Device details" are stored as txt files. The IP address of your unit can be found on the Info screen. Click on the "Service" button in the header line of the main menu. The dialog box for entering the access data opens. Enter the following access data: Username: service Password: "sirona" 7.
Confirm your entry by clicking the "OK" button. The sub menus of the "Service" menu are displayed in the structure tree. The following submenus are displayed in the structure tree: "Backup sensor data" "Restore sensor data" "Install new sensor data" The "Backup sensor data" submenu is preselected.
The submenus and their functions are explained in more detail in the chapters below. The stored sensor data must then be restored on the new DX83 board after replacing the board. This can be done [ 74] via the menu "Restore sensor data".
Save sensor data2. In the structure tree, click on the "Backup sensor data" element. Click on the "Backup sensor data" button. The "Download Backup" menu opens. A selection dialog box opens in your browser. Confirm the selection by clicking the "OK" button. If no complete unit adjustment and calibration has been performed, no patient images are possible. To that end, the sensor data must have been backed up [ 73] before replacing the DX83 board using the "Backup sensor data" menu.
In the structure tree, click on the "Restore sensor data" element. The "Restore sensor data" menu is displayed. Click on the "Select File" button and select the desired Zip file in the directory refer to chapter Backing up sensor data [ 73].
Click on the "Restore" button. The sensor data stored in the Zip file is restored on the DX83 board. Perform a complete unit adjustment and calibration [ ]. NOTE: As the sensor data is stored on the DX83 board, this is necessary, for example, after changing the flat panel detector. The corresponding Zip file is included in the scope of supply of the new flat panel detector.
In the structure tree, click on the "Install new sensor data" element. Click on the "Select File" button and select the desired Zip file that contains the sensor data for the new flat panel detector in the directory. Click on the "Install" button. The sensor data stored in the Zip file is installed on the DX83 board. The touchscreen display is located on level 1.
Touch the toothed wheel A in the upper right corner of the A touchscreen. The touchscreen display is located on level 2. Touch the question mark B in the lower right corner of the touchscreen. The info screen is displayed. Touch the arrows C in the scroll bar to the right of the list. The next or previous page of the list is displayed. Touch the double triangle in the upper right corner of the C touchscreen.
The display changes to level 1. Please wait. For this reason, you must take the following safety measures: 1. Turn the unit off. It is essential to switch off the unit and to wait at least another 4 minutes before taking off the covers of the X-ray tube assembly. Remove the "Tube assembly, cover" cover [ 37]. Remove the cover plate of board DX6 [ ]. Set dip switch S2 DX6 to position 2. Radiation release is now no longer possible.
Switch on the unit and check the mode on the info screen. Demo mode: ON means that: Demo mode is switched on radiation release is not possible Demo mode: OFF means that: Demo mode is switched off radiography, X-ray radiation are possible! Switch the unit off again and reattach the cover plate and the tube assembly cover by following the dismantling procedure in reverse order. Switch off the unit. Remove the "Rear tube assembly" cover [ 37]. Set the dip switch S2 DX6 to position 1.
Radiation release is now once again possible. Packing the cephalometer 1. Call service routine S After calling the service routine, an inactive progress indicator is displayed in selection field 1.
Selection field 2 shows the characters "FFFF". Touch the T key A. The cephalometer moves to the packing position. The procedure is visualized by an active progress indicator in selection field 1. Exit the service routine. The bottom edge of the slide cover must be at the same height as the markings in the column. Be sure to switch off the line power supply before connecting the line voltage!
Pack the panoramic X-ray unit For packing condition, refer to the "Delivery" section of the installation manual. Attaching the transport safety device Install the transport safety device by following the same procedure as Dismantling in reverse order. There are 3 groups of message texts: Help messages Hx xx : Auxiliary messages request an action, e.
H3 20 acknowledge exposure data. Error messages Ex yyxx : Error messages indicate unit faults. The user must take action to eliminate the fault s. The codes tell you how to operate the system if radiation release is not possible. The following list provides you with an overview of all help codes, their meaning and the action required to eliminate the corresponding problems.
If it is not possible to clear a message by taking the measures listed, another type of error is the cause. In such cases, you should run an error diagnosis [ ]. Unit moves to starting position. H3 07 "Change bite block" Remove the occlusal bite block.
H3 20 "R button, confirm exposure data" Press the Return key. Exposure data are confirmed. H3 21 "Close the door" Close door or check door contact. Then press R key to acknowledge the message. H3 22 "Select quadrant" Select quadrant H3 25 "Select region of exposure" Select the center of rotation. H4 02 "Plug sensor into Ceph slot" Check the ceph sensor or plug it into the cephalometer. If this message does not disappear even after the ceph sensor has been plugged in, this indicates a system error.
Perform error diagnosis as described in the section titled Troubleshooting [ ]. H4 04 "Plug in Ceph sensor" Plug the ceph sensor into the cephalometer. The codes provide you with error type, error location and troubleshooting information. Ex Error type Troubleshooting classification for the user yy Location Module, subsystem or logical function unit zz Consecutive Identification of error number. Switch unit on. Repeat procedure If the error occurs again Run an error diagnosis [ 84].
The cause of the error disappears automatically after a If the error occurs again Extend the waiting time. If the error occurs again Repeat the last procedure step or exposure. They may be caused by Further operation of the unit is possible. They may be caused by system self-tests. In this case it is absolutely certain that continued system operation is not possible.
If trouble-free operation is possible after the error is acknowledged, then no further action is necessary. If error messages occur again or frequently, or if fault-free operation is not possible, run an error diagnosis see chapter Troubleshooting [ ]. For enhanced clarity, the corresponding ID in the error code is printed in bold type.
If the error occurs repeatedly Error code Description Actions required see E6 06 E6 06 02 Invalid system data or uninitialized Run service routine S Please also observe the software update is possible and causal error message!
It appears perform such an update if necessary. E6 06 05 Data transfer error or dialog error to Repeat the software update. Replace the tube assembly. Check power supply of board DX11; The module was temporarily not measuring point 3. Master DX11 receives no If 3. Please also observe the Check tube assembly DX6 , replace if S. It appears necessary. CAN controller Check software versions on the info S. Please contact the Sirona Customer S. Error code Description Actions required see E7 06 Please also observe the Restart the unit: causal error message!
It appears only after you acknowledge the first 1. Repeat procedure and observe causal error messages. Stored data may be lost. Error code Description Actions required see E2 06 Check fan function by running service S. Check temperature sensor in single S. E6 06 21 Hardware signal of release button Check cable L5 optical fiber , replace S. E6 06 22 Broken temperature sensor Replace the tube assembly.
Error code Description Actions required see E3 06 E3 06 23 Hardware signal of release button Check cable L5: applied during power-on. Pull cable L5 off tube assembly. Perform optical check of L5: If light is visible If no light is visible Error code Description Actions required see E5 06 Check the CAN bus.
Error code Description Actions required see E1 06 E1 06 40 Tolerance exceeded Run service routine S E1 06 41 Tolerance exceeded kV nom. Run service routine S E1 06 42 Tolerance exceeded Run service routine S E1 06 43 Tolerance exceeded Run service routine S E1 06 44 Tolerance exceeded kV actual Run service routine S E1 06 45 Tolerance exceeded mA actual Run service routine S E6 06 51 VHmax limit value exceedance Run service routine S E6 06 52 Limit value exceedance Run service routine S E6 06 53 Limit value exceedance Run service routine S E6 06 54 Basic heating pulses not applied.
E6 06 55 Anode voltage too low. E6 06 56 Error during auto-compensation. Let the tube assembly cool down for approx. Replace board DX1. E6 06 65 Tube current or tube voltage is too Replace the tube assembly. E6 06 66 Impermissible tube type. Check tube type of tube assembly S. Disconnect cable L15 at board DX Error code Description Actions required see E6 07 Therefore: avoid direct sunlight and bright room lighting above the unit!
Reattach all covers. When attaching the covers: be sure to screw the sheet metal cover back on. Exposure time: See "Program values". Image acquisition scale: For P1, normal dental arch slice center approx. Exposure time for a Depending on the tube load, interval times of 8 s to s are automatically set by the system. Example: For program P1 with exposure. Equipment class: IPX0 Protection class. Class I device Degree of protection against electric shock: Type B device Degree of protection against Ordinary equipment without protection ingress of water: against ingress of water Year of manufacture:.
Active sensor area, Pan type: x 6 mm Pixel size: 0. Digital Flat Panel Detector with a-Si technology amorphous silicon. With 3D exposure technology: Active sensor area mm x mm Pixel size: 0. Active sensor area, Ceph mm x 6. Processor 2. If a module software version does not match the main software version, the main software version is identified with an asterisk on the info screen e. Main software V No person may be positioned in the unit when it is switched on. NOTICE Damage to the unit Make sure that no objects are in the movement range of the device when it moves exception: Calibration block and positioning aids.
Electrical components are destroyed by short circuits. Do not switch the unit on until the temperature of the unit has adapted to the ambient temperature and the condensation has evaporated.
Also note the operating temperature specified for this device. Constant switching on and off reduces the service life of individual unit components and results in increased power consumption. After switching the unit off, wait for approx. The touchscreen can be damaged or its surface scratched. Never use pointed objects such as ballpoint pens, pencils, etc. Only use your fingertips to operate the touchscreen. At the same time, the self-adjustment routine for the mechanics and the electronics of the unit is performed.
If a key is pressed during the self- adjustment routine, an error message will display on the control panel. Turn the main switch A to position I. Wait for approx. A B The radiation indicator X-ray C lights up for approx. For a number of seconds the height adjustment keys light up blue, then quickly change to green.
After approx. This LED remains lit as long as the unit is on. The start screen is displayed on the touchscreen for several seconds. The program selection is then displayed on the touchscreen. The forehead support and temple supports are completely open. Check whether the patient symbols on the touchscreen can be selected in exactly the right position.
If problems occur during selection, adjust the touchscreen [ ]. English is preconfigured as the unit language. The preview image is switched on. The welcome screen is switched on.
The first name, last name and date of birth lines are displayed on the welcome screen. Ambient light background lighting is set to "white". If the customer requires a different configuration, this can be implemented via service routine S or the Web service ambient light. Each X-ray component must be assigned a unique IP address and the name of the X-ray component must also be unique.
To find out whether an IP address already exists in the network, enter the. Switch on all network devices computers, printers, X-ray components which have been operated to date.
Invoke the input prompt DOS window from a network computer. At the prompt, enter "ping" followed by the address to be checked and then press the Enter key. Example: ping The "Sirona AcquisitionServer" software is installed. If necessary: Select the acquisition server from the "Acquisition Server" list field. Click on the "Next" button. A password dialog box appears. Enter the service password and confirm your input by clicking the "OK" button. Menu for adding X-ray components The menu for adding X-ray components opens.
There are three options for adding X-ray components: "Automatic search" "Boot service" "Add device manually". The menu for adding X-ray components opens.
Click the "Automatic search" button in the structure tree. The network is searched for available X-ray components. The X-ray components found on the network are displayed in list form. NOTE: If no X-ray component is found, check the availability of the unit and repeat the "Automatic search" or use the "Add device manually" function.
Selecting an X-ray component 2. Select the preferred X-ray component and enter "Location" in the text box in the location of the X-ray component. Click the "Save" button to save the settings. Wait until the saving operation has been completed. Then click the button marked "Exit". The menu closes. Click on the "Cancel" button. Click the "Boot service" button in the structure tree. A message window prompts you to switch the new X-ray component back on to reboot.
The network is searched for the "booting" X-ray component. The X-ray components found in the network is displayed with their network data. Adapt the network configuration IP address, subnet mask and the standard gateway to your network. If you receive an error message when saving the network configuration, the network data entered are probably invalid. Repeat the entire procedure with valid network data.
Click the "Add device manually" button in the structure tree. The workstation software for the corresponding X-ray component or sensor is installed on the workstation. Click on the "Device configuration" button.
The "Device configuration" menu opens. Click on the "Device details" button in the structure tree and then on the "Show Information" button. Click on the "Downloading" button to load and save the current unit information for the unit. You have a certificate containing a valid activation key code. A Level 1 is displayed on the touchscreen.
Touch the toothed wheel A in the selection image. Level 2 is displayed. Touch the keyboard icon B. B A keyboard then appears. Enter the activation key from the certificate via the keyboard. C Once the final character is entered, the enter key C appears. Tip: The activation key code consists of 16 characters. Confirm your input with the Enter key C. The function enhancement is activated. If the entry contains errors,! The function enhancement has failed. Compare the activation key code displayed with the activation key code on the certificate.
If you cannot detect an input error, contact the responsible sales partner. A Level 2 is displayed. Touch the question mark in the bottom right corner. G The name of the function enhancement is displayed. As an alternative to entering the access code via the Easypad, the activation key code can also be entered via an internet browser.
The unit and computer are turned on. The unit is logged into the network as an X-ray component. Start an Internet browser such as Internet Explorer or Firefox. Confirm your input with the "Enter" key. A security prompt appears. Click on the link "Continue to this Website".
NOTE: Javascript must be enabled. The Sirona Web service is loaded. The sub menus of the "User" menu are displayed in the structure tree. In the structure tree, click on the "ActivationCode" element.
A page with an input field is opened. Enter the activation key code from the certificate in the field. Confirm your entry with the "Enter ActivationCode" button. The first time you establish contact with the X-ray device, a certificate check operating system function should be performed. If no certificate check has been performed, the "Security Alert" dialog box is displayed every time a connection is established to the X-ray device.
The "Security Alert" dialog box is opened. Click on the "View Certificate" button. The "Certificate" dialog box opens. Click on the "Install Certificate" button.
The "Certificate Import Wizard" opens. Select the "Automatically select the certificate store based on the type of certificate" option panel. Click on the "Finish" button. The "Security Warning" window then opens. If the fingerprint matches, click on the "Yes" button. If the fingerprint does not match, contact your local sales partner.
The confirmation window opens with the message "The import was successful". Click on the "OK" button. The certificate check has been performed. Unit inoperability! Before starting the firmware update, make sure that no unit movements are active. Otherwise the system may become inoperable in rare cases. The sensor unit must be installed as part of the update. These sources always contain the latest information on software updates.
Starting the software update 3. Select the desired X-ray component in the list marked "Device administration". Then click on the "Software update" button. The dialog box for entering the service password opens. Enter the first 4 digits of the current system date in reverse order e. Enter the service password. Click the "OK" button to confirm the entry. The connection to the Acquisition Server is established.
The update menu opens. Click on the "Browse" button and select the desired update file. The update file is located on the unit software CD. It is delivered with each DX11 replacement board and also included in the country set. Click on the "Update starten" button to start the firmware update The firmware update is started.
A dialog window showing the progress tells you the status of the upload. After the firmware update, the message window in the update menu shows whether the update was successful or not. In addition, a message in the software manager notifies you that a unit restart is required to activate the firmware update you performed. A new DX11 or DX83 version will run only after the unit has been rebooted see also chapter "Measures following replacement of boards [ ]".
Any errors with the consecutive numbers 01, 03, 04, 06, or 07 displayed immediately following the firmware update may be ignored.
If these messages appear again after the system is rebooted, please carry out troubleshooting as described in the "List of error messages [ 84]" section. If any conspicuous problems occur in connection with system handling after the firmware update and unit reboot has been completed, please repeat the firmware update immediately. After a successful firmware update, the log file produced by the unit is displayed in the update menu.
Check the log file to make sure that the update was completed successfully. If the log file contains entries such as "Update of DXxx failed! Repeat this procedure as often as necessary until the "failed messages" no longer appear. Restart the unit now. Use the "Device details" or service routine S If you want to save the "Device details" : Open the "Device details" [ 59]. Click on the "Show Information" button. Click on the "Download" button.
Select the storage location you desire. Click on the "Save" button. The "Device details" are stored as txt files. The IP address of your unit can be found on the Info screen.
Click on the "Service" button in the header line of the main menu. The dialog box for entering the access data opens. Enter the following access data: Username: service Password: "sirona" 7. Confirm your entry by clicking the "OK" button. The sub menus of the "Service" menu are displayed in the structure tree. The following submenus are displayed in the structure tree: "Backup sensor data" "Restore sensor data" "Install new sensor data" The "Backup sensor data" submenu is preselected.
The submenus and their functions are explained in more detail in the chapters below. The stored sensor data must then be restored on the new DX83 board after replacing the board. This can be done [ 74] via the menu "Restore sensor data". Save sensor data2. In the structure tree, click on the "Backup sensor data" element. Click on the "Backup sensor data" button. The "Download Backup" menu opens. A selection dialog box opens in your browser. Confirm the selection by clicking the "OK" button.
If no complete unit adjustment and calibration has been performed, no patient images are possible. To that end, the sensor data must have been backed up [ 73] before replacing the DX83 board using the "Backup sensor data" menu.
In the structure tree, click on the "Restore sensor data" element. The "Restore sensor data" menu is displayed. Click on the "Select File" button and select the desired Zip file in the directory refer to chapter Backing up sensor data [ 73]. Click on the "Restore" button.
The sensor data stored in the Zip file is restored on the DX83 board. Perform a complete unit adjustment and calibration [ ]. NOTE: As the sensor data is stored on the DX83 board, this is necessary, for example, after changing the flat panel detector. The corresponding Zip file is included in the scope of supply of the new flat panel detector. In the structure tree, click on the "Install new sensor data" element.
Click on the "Select File" button and select the desired Zip file that contains the sensor data for the new flat panel detector in the directory. Click on the "Install" button. The sensor data stored in the Zip file is installed on the DX83 board. The touchscreen display is located on level 1. Touch the toothed wheel A in the upper right corner of the A touchscreen.
The touchscreen display is located on level 2. Touch the question mark B in the lower right corner of the touchscreen. The info screen is displayed. Touch the arrows C in the scroll bar to the right of the list. The next or previous page of the list is displayed. Touch the double triangle in the upper right corner of the C touchscreen. The display changes to level 1. Please wait. For this reason, you must take the following safety measures: 1.
Turn the unit off. It is essential to switch off the unit and to wait at least another 4 minutes before taking off the covers of the X-ray tube assembly. Remove the "Tube assembly, cover" cover [ 37]. Remove the cover plate of board DX6 [ ].
Set dip switch S2 DX6 to position 2. Radiation release is now no longer possible. Switch on the unit and check the mode on the info screen. Demo mode: ON means that: Demo mode is switched on radiation release is not possible Demo mode: OFF means that: Demo mode is switched off radiography, X-ray radiation are possible! Switch the unit off again and reattach the cover plate and the tube assembly cover by following the dismantling procedure in reverse order.
Switch off the unit. Remove the "Rear tube assembly" cover [ 37]. Set the dip switch S2 DX6 to position 1. Radiation release is now once again possible. Packing the cephalometer 1. Call service routine S After calling the service routine, an inactive progress indicator is displayed in selection field 1. Selection field 2 shows the characters "FFFF". Touch the T key A. The cephalometer moves to the packing position. The procedure is visualized by an active progress indicator in selection field 1.
Exit the service routine. The bottom edge of the slide cover must be at the same height as the markings in the column. Be sure to switch off the line power supply before connecting the line voltage!
Pack the panoramic X-ray unit For packing condition, refer to the "Delivery" section of the installation manual. Attaching the transport safety device Install the transport safety device by following the same procedure as Dismantling in reverse order.
There are 3 groups of message texts: Help messages Hx xx : Auxiliary messages request an action, e. H3 20 acknowledge exposure data. Error messages Ex yyxx : Error messages indicate unit faults. The user must take action to eliminate the fault s. The codes tell you how to operate the system if radiation release is not possible.
The following list provides you with an overview of all help codes, their meaning and the action required to eliminate the corresponding problems. If it is not possible to clear a message by taking the measures listed, another type of error is the cause.
In such cases, you should run an error diagnosis [ ]. Unit moves to starting position. H3 07 "Change bite block" Remove the occlusal bite block. H3 20 "R button, confirm exposure data" Press the Return key. Exposure data are confirmed. H3 21 "Close the door" Close door or check door contact. Then press R key to acknowledge the message.
H3 22 "Select quadrant" Select quadrant H3 25 "Select region of exposure" Select the center of rotation. H4 02 "Plug sensor into Ceph slot" Check the ceph sensor or plug it into the cephalometer.
If this message does not disappear even after the ceph sensor has been plugged in, this indicates a system error. Perform error diagnosis as described in the section titled Troubleshooting [ ]. H4 04 "Plug in Ceph sensor" Plug the ceph sensor into the cephalometer. The codes provide you with error type, error location and troubleshooting information. Ex Error type Troubleshooting classification for the user yy Location Module, subsystem or logical function unit zz Consecutive Identification of error number.
Switch unit on. Repeat procedure If the error occurs again Run an error diagnosis [ 84]. The cause of the error disappears automatically after a If the error occurs again Extend the waiting time.
If the error occurs again Repeat the last procedure step or exposure. They may be caused by Further operation of the unit is possible. They may be caused by system self-tests. In this case it is absolutely certain that continued system operation is not possible. If trouble-free operation is possible after the error is acknowledged, then no further action is necessary. If error messages occur again or frequently, or if fault-free operation is not possible, run an error diagnosis see chapter Troubleshooting [ ].
For enhanced clarity, the corresponding ID in the error code is printed in bold type. If the error occurs repeatedly Error code Description Actions required see E6 06 E6 06 02 Invalid system data or uninitialized Run service routine S Please also observe the software update is possible and causal error message! It appears perform such an update if necessary. E6 06 05 Data transfer error or dialog error to Repeat the software update. Replace the tube assembly. Check power supply of board DX11; The module was temporarily not measuring point 3.
Master DX11 receives no If 3. Please also observe the Check tube assembly DX6 , replace if S. It appears necessary. CAN controller Check software versions on the info S.
Please contact the Sirona Customer S. Error code Description Actions required see E7 06 Please also observe the Restart the unit: causal error message! It appears only after you acknowledge the first 1. Repeat procedure and observe causal error messages. Stored data may be lost. Error code Description Actions required see E2 06 Check fan function by running service S. Check temperature sensor in single S. E6 06 21 Hardware signal of release button Check cable L5 optical fiber , replace S.
E6 06 22 Broken temperature sensor Replace the tube assembly. Error code Description Actions required see E3 06 E3 06 23 Hardware signal of release button Check cable L5: applied during power-on.
Pull cable L5 off tube assembly. Perform optical check of L5: If light is visible If no light is visible Error code Description Actions required see E5 06 Check the CAN bus. Error code Description Actions required see E1 06 E1 06 40 Tolerance exceeded Run service routine S E1 06 41 Tolerance exceeded kV nom. Run service routine S E1 06 42 Tolerance exceeded Run service routine S E1 06 43 Tolerance exceeded Run service routine S E1 06 44 Tolerance exceeded kV actual Run service routine S E1 06 45 Tolerance exceeded mA actual Run service routine S E6 06 51 VHmax limit value exceedance Run service routine S E6 06 52 Limit value exceedance Run service routine S E6 06 53 Limit value exceedance Run service routine S E6 06 54 Basic heating pulses not applied.
E6 06 55 Anode voltage too low. E6 06 56 Error during auto-compensation. Let the tube assembly cool down for approx. Replace board DX1. E6 06 65 Tube current or tube voltage is too Replace the tube assembly. E6 06 66 Impermissible tube type. Check tube type of tube assembly S. Disconnect cable L15 at board DX Error code Description Actions required see E6 07 Acknowledge error and repeat procedure. E6 07 03 Invalid commanding or control data.
Please also observe the whether a bug fix by means of a causal error message! It appears software update is possible and only after you acknowledge the first perform such an update if necessary. E6 07 05 Data transfer error or dialog error to Repeat the software update. Procedure error in the software If 3.
Please also observe the causal error message! It appears only after you acknowledge the first error message. Replace Easypad DX7. Error code Description Actions required see E7 07 E6 07 20 Contact to DX11 interrupted during Note error message on remote control operation.
DX42 and check log memory via extended details. E7 07 21 No CAN bus connection. DX11 does Checking "Unit information" S. A unique, lead-impregnated acrylic shield protects the operator from direct and scatter radiation while an internal proprietary housing encases the X-ray tube to block radiation leakage.
We know that you want to render the best diagnosis to your patients, and the best diagnosis starts with the best image quality. Freedom is in your hands with the ability to take an X-ray anywhere out of the office and in any treatment area in your practice. This innovatively designed unit allows you to stay with your patient during the procedure, especially with fearful or challenging patients. No more leaving the room to trigger exposures only to return to find that the X-ray head has drifted or that your patient has moved necessitating a retake of the radiograph.
With your new handheld system, you can save on the cost and time of special construction, wiring, and installation. Proudly manufactured in the U. With our past successes and award-winning design, KaVo NOMAD continues to be widely accepted in this rapidly growing area in dental technology. Using vital safety and engineering research data, our company has been instrumental in moving this technology forward so that dentists can have the freedom that KaVo NOMAD products offer.
This higher-capacity battery uses technology commonly employed in industrial power tools and is designed to keep pace with the demands of busy dental practices and workflow even in heavy usage.
The battery cells, similar to those used in electric vehicles, are constructed of the latest advanced materials. The battery charger has been newly developed for maximum charging power to yield the most efficient use of the system.